Insulating a radiant slab (C) Daniel Friedman Phase Change Floor Tiles for Passive Solar

Passive solar floor heating using phase change floor tiles:

This article discusses the use of phase-change floor tiles for passive solar floor design

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

Passive Solar Floor Tile Choices - Phase-Change Tiles

Accompanying text are reprinted/adapted/excerpted with permission from Solar Age Magazine - editor Steven Bliss. Our page top photograph shows a horrible radiant floor slab insulation scheme installed by a Minnesota contractor - this radiant floor system never worked because the tubing was placed too deep in the concrete slab and the insulation system was incomplete.

Floor Coverings for Passive Solar Thermal Mass Floors

The question-and-answer article below paraphrases, quotes-from, updates, and comments an original article from Solar Age Magazine and written by Steven Bliss.

Question:

A few years ago I read about floor tiles with phase-change salts inside their hollow cores for use over thermal-mass slabs in passive solar heating designed homes.

An upcoming project I'm involved in could benefit from such a project. Could you please supply me with information on suppliers or manufacturers of phase-change floor tiles for use over insulated slabs? -- Gary Higgins, North Windham ME

Answer:

We mentioned Sol-Ar-Tile™ in Solar Age articles in February 1982 (p.40), and May 1983 (p. 69).

The manufacturer, Ar-Lite Panelcraft Inc., (formerly Architectural Research Corp.), uses Colloidal Material's pouches in polymer resin concrete tiles for floors and ceilings.

Penwalt Corp. produces and packages phase-change materials that can be embedded in floors, ceilings, and walls.

Other articles you'll want to see on passive solar floors, ceilings, and walls, include

The question-and-answer article about use of phase-change materials in passive solar house design, quotes-from, updates, and comments an original article from Solar Age Magazine and written by Steven Bliss.

The link to the original Q&A article in PDF form immediately below is followed by an expanded/updated online version of this article.


...

Continue reading at PASSIVE SOLAR HEAT PERFORMANCE or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.

Suggested citation for this web page

PASSIVE SOLAR FLOOR TILES, PHASE CHANGE at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.


Or see this

INDEX to RELATED ARTICLES: ARTICLE INDEX to SOLAR ENERGY

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia

Ask a Question or Search InspectApedia

Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.

Search the InspectApedia website

Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.

Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification
when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca

Comment Form is loading comments...

Citations & References

In addition to any citations in the article above, a full list is available on request.



ADVERTISEMENT