No heat or weak heat checklist for gas-fired heating furnaces.
This article gives a series of quick and easy checks and repairs for gas fired heating furnaces. The no-heat or weak heat or uneven-heat complaints experienced by most homeowners will be addressed by these easy troubleshooting steps. The text also discusses common sources of indoor condensation on windows or walls where gas fired heaters are installed and includes some important safety warnings where you see condensation indoors.
Some no-heat or inadequate-heat complaints can be easily resolved without having to call a repairman. We include safety warnings and we indicate where a service call for heat repair is almost certainly needed.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
Gas Furnace Troubleshooting Checklist |
||
Watch out: Immediate LP or natural gas safety hazards: if there is evidence of an LP or natural gas leak at a building, gas odors, for example, you should: Do not do anything that is likely to cause a gas explosion, such as lighting a match, operating an electrical switch, or even using a telephone in the building |
||
No Heat or Not Enough Heat from the furnace |
||
Possible Cause | Action | Comments & More Help |
Furnace won't turn on | Check that power is on to the unit | Some WALL-MOUNTED FURNACES can operate without external electrical power. |
Thermostat not properly set | Set thermostat to above current room temperature. Check that thermostat is set to HEAT mode. | THERMOSTATS, HEATING / COOLING |
Pilot light is out | Check pilot, re-light. Check that fuel supply is turned on. |
If pilot won't stay lit, check fuel supply. |
Pilot on, burner won't turn on | Check that gas valve is set to ON, not PILOT | GAS REGULATORS for APPLIANCES |
Burner not operating properly: noisy, incomplete, uneven, weak flame, flame lifts off burner. | Service call required. | GAS BURNER FLAME & NOISE DEFECTS |
Insufficient warm air circulation from the gas furnace |
||
Possible Cause | Action | Comments & More Help |
Dirty air filter | Clean or replace the air filter | |
Air supply registers obstructed | Clean dirty register outlet grilles; remove blocking furniture, carpet, etc. | AIR FLOW IMPROVEMENT, HVAC |
Return air registers obstructed | Clean dirty register return air inlet grilles; remove blocking furniture, carpet, etc. | RETURN AIR, INCREASE |
Dirty blower fan | Clean dirty blower fan assembly. Small amount of dirt greatly decreases air movement | DIRTY A/C BLOWERS |
Floors are too cold |
||
Possible Cause | Action | Comments & More Help |
Blocked return air inlets | RETURN AIR, INCREASE | |
Dirty air filter | Clean or replace the air filter | |
Inadequate air circulation: warm at ceiling cool at floor | Set blower for continuous operation | BLOWER FAN CONTINUOUS OPERATION |
Noisy Furnace: blower or burner noises |
||
Possible Cause | Action | Comments & More Help |
Noisy blower fan | Blower may need oiling Blower fan bearings loose, worn Blower is dirty or air filter is dirty, clogged |
|
Noisy gas burner | Service call required , gas regulator defect, combustion air defect | Watch out: : system may be unsafe. Shut it down. |
Moisture condensing on windows or walls - gas fired heat |
||
Possible Cause | Action | Comments & More Help |
Blocked chimney or exhaust vent | Inspect & clear, repair, replace improper venting. Service call required. |
Watch out: : the heating system is likely to be unsafe. Shut it down. |
Combustion air inadequate | Service call required. | Watch out: : the heating system is unsafe. Shut it down. |
Insufficient ventilation, tight house. | Service call required. | Watch out: : the heating system may be unsafe. Shut it down. |
Humidifier improperly set | Check power humidifier or free-standing humidifier settings. | Also see DUCT & AIR HANDLER ODORS |
Watch out: improper installation and even improper inspection and testing methods involving natural or "LP" gas can involve dangerous conditions and risk fire or explosion.
See DIAGNOSE & FIX HEATING PROBLEMS-FURNACE for complete diagnostic & inspection guides
Adapted from Sears Corporation, "Sears Gas Furnace Service Hints", (1993), provided courtesy Jim Jagger, ASHI, Buckeye Home Inspections, Cleveland OH, Tel: 216-486-4663. Sears Gas-Fired "Space Saver"Furnace Models: 867.765030 - 867.775260.
Below you will find questions and answers previously posted on this page at its page bottom reader comment box.
On 2021-02-11 by Green Leaf Air
Green Leaf Air said:
This article gives a series of quick and easy checks and repairs for gas-fired heating furnaces. The no-heat or weak heat or uneven-heat complaints experienced by most homeowners will be addressed by these easy troubleshooting steps.
Moderator note: Thank you Green Leaf: while our policy does not permit readers to post self-promotions, ads, links, we welcome content criticism, suggestions, comments and are happy to identify and link to such technical contributors.
On 2019-01-24 by john
We have a 16 year old Armstrong condensing gas furnace. When started by the thermostat it would initially run a blower to clear the firebox for a few seconds before the gas would be released and ignited, and then after a short period the main blower would turn on. Now recently the main blower turns on instantly when unit is asked to heat. This sounds like a problem to me??
On 2019-01-06 by - by (mod) -
friedman (mod)This sounds as if the system is overheating and being shut down by the fan limit controller. Replace the air filter, clean the blower fan and confirm that the ductwork is not crimped or disconnected, and that there's plenty of return air, and let me know if that fixes the trouble.
On 2019-01-04 by willie
I have an old gaffers & sattler u80 the burnners light for about 30 sec.then shutts off then the fan kicks on for 60 sec.then shuts off then starts again about 5 min. later
On 2018-12-09 by (mod) - Pilot light flickering
Dirty orifice
Loose connection
Improper placement
Low fuel?
On 2018-12-09 by kathy
Pilot light flickering
On 2018-12-01 by - by (mod) -
friedman (mod)Jerry
See BLOWER FAN WONT STOP
inspectapedia.com/heat/Furnace_Fan_Wont_Stop.php
where we List the common causes of that problem. Take a look at that article and let me know if I can be of further help.
On 2018-12-01 by Jerry
What caused the furnace blower to run not shut off
On 2016-11-07 by Anonymous
the burner on my wall furnace will go out unexpectedly
...
Continue reading at DIAGNOSE & FIX FURNACE PROBLEMS or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
FURNACE DIAGNOSTIC CHECKS, GAS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca
In addition to any citations in the article above, a full list is available on request.